Hi Folks,
I couldn't understand properly about SRW.REFERENCE and SRW.USER_EXIT even I red about it in the reports manual. My question is why,where,and which condetion we can use this.Moreover, what is the purpose of this. If anyone knows, please post your valuble explanation. I would be very thankful to you.
Thanks,
Chaitanya.
SRW.REFERENCE and SRW.USER_EXIT
SRW.REFERENCE: This procedure causes Report Builder to add the referenced object to the PL/SQL construct's dependency list. This causes Report Builder to determine the object's value just before firing the PL/SQL construct. This is useful when you want to ensure that a column value passed to a user exit is the most recently computed or fetched value.
/* Suppose you want to pass the temperature and pressure values
** to a user exit called SUPERHEAT. Suppose, also, that if the
** temperature is too low, you want to raise a customized error message.
** To do so, you could write the following formula:
*/
FUNCTION EXIT RETURN BOOLEAN IS
BEGIN
if :temp > 0 then
srw.reference (:temp); -- unnecessary reference
srw.reference (:pressure);
srw.user_exit('superheat temp pressure');
else srw.message(1000, 'Temperature is below
normal. Is machine off?');
raise srw.program_abort;
end if;
RETURN(TRUE);
END;
----
SRW.USER_EXIT: This procedure calls the user exit named in user_exit_string. It is useful when you want to pass control to a 3GL program during a report's execution.
/* Suppose you have a user exit named STORE to which you want
** to pass salary values from Report Builder. To do so, you
** could write the following formula. For more information on
** how to call user exits, see Calling a user exit.
*/
FUNCTION FOO RETURN BOOLEAN IS
BEGIN
IF :SAL >= 0 THEN
SRW.REFERENCE(:SAL);
SRW.USER_EXIT('STORE SAL');
ELSE
SRW.MESSAGE(100, 'FOUND A NEGATIVE SALARY. CHECK THE
EMP TABLE.');
END IF;
EXCEPTION
WHEN SRW.UNKNOWN_USER_EXIT THEN
SRW.MESSAGE(200, 'STORE USER EXIT WAS UNKNOWN.
CHECK IF IT''S LINKED.');
WHEN SRW.USER_EXIT_FAILURE THEN
SRW.MESSAGE(200, 'STORE USER EXIT FAILED.
CHECK ITS CODE.');
RETURN(TRUE);
END;
Pl let us know what is the confusion after reading/experimenting example the reports help as shown above. thanks
/* Suppose you want to pass the temperature and pressure values
** to a user exit called SUPERHEAT. Suppose, also, that if the
** temperature is too low, you want to raise a customized error message.
** To do so, you could write the following formula:
*/
FUNCTION EXIT RETURN BOOLEAN IS
BEGIN
if :temp > 0 then
srw.reference (:temp); -- unnecessary reference
srw.reference (:pressure);
srw.user_exit('superheat temp pressure');
else srw.message(1000, 'Temperature is below
normal. Is machine off?');
raise srw.program_abort;
end if;
RETURN(TRUE);
END;
----
SRW.USER_EXIT: This procedure calls the user exit named in user_exit_string. It is useful when you want to pass control to a 3GL program during a report's execution.
/* Suppose you have a user exit named STORE to which you want
** to pass salary values from Report Builder. To do so, you
** could write the following formula. For more information on
** how to call user exits, see Calling a user exit.
*/
FUNCTION FOO RETURN BOOLEAN IS
BEGIN
IF :SAL >= 0 THEN
SRW.REFERENCE(:SAL);
SRW.USER_EXIT('STORE SAL');
ELSE
SRW.MESSAGE(100, 'FOUND A NEGATIVE SALARY. CHECK THE
EMP TABLE.');
END IF;
EXCEPTION
WHEN SRW.UNKNOWN_USER_EXIT THEN
SRW.MESSAGE(200, 'STORE USER EXIT WAS UNKNOWN.
CHECK IF IT''S LINKED.');
WHEN SRW.USER_EXIT_FAILURE THEN
SRW.MESSAGE(200, 'STORE USER EXIT FAILED.
CHECK ITS CODE.');
RETURN(TRUE);
END;
Pl let us know what is the confusion after reading/experimenting example the reports help as shown above. thanks
Thanks Admin, I understood the srw.reference.See this formula column
function INV_LINE_DISPFormula return Char is
begin
srw.reference(:INV_LINE);
srw.reference(:inv_curr);
srw.reference(:INV_CURR_PRECISION);
srw.user_exit('FND FORMAT_CURRENCY
CODE=":inv_curr"
DISPLAY_WIDTH="16"
AMOUNT=":INV_LINE"
DISPLAY=":INV_LINE_DISP"
MINIMUM_PRECISION=":INV_CURR_PRECISION"');
return(:INV_LINE_DISP);
end;
function INV_LINE_DISPFormula return Char is
begin
In srw.reference,:INV_LINE, :inv_curr, and :INV_CURR_PRECISION are place holders. I understood this but, in srw.user_exit, the user_exit name FND is used. what is the purpose of this and even some placeholders are not in srw.reference , was used in srw.user_exit(DSPLAY_WIDTH="16",DISPLAY=":INV_LINE_DISP"
);
I wont understand about the user_exit_string in srw.user_exit.
Thanks,
Chaitanya.
function INV_LINE_DISPFormula return Char is
begin
srw.reference(:INV_LINE);
srw.reference(:inv_curr);
srw.reference(:INV_CURR_PRECISION);
srw.user_exit('FND FORMAT_CURRENCY
CODE=":inv_curr"
DISPLAY_WIDTH="16"
AMOUNT=":INV_LINE"
DISPLAY=":INV_LINE_DISP"
MINIMUM_PRECISION=":INV_CURR_PRECISION"');
return(:INV_LINE_DISP);
end;
function INV_LINE_DISPFormula return Char is
begin
In srw.reference,:INV_LINE, :inv_curr, and :INV_CURR_PRECISION are place holders. I understood this but, in srw.user_exit, the user_exit name FND is used. what is the purpose of this and even some placeholders are not in srw.reference , was used in srw.user_exit(DSPLAY_WIDTH="16",DISPLAY=":INV_LINE_DISP"
);
I wont understand about the user_exit_string in srw.user_exit.
Thanks,
Chaitanya.
Who is online